Conserve® Plus hip resurfacing shows
durable socket fixation for Developmental Dysplasia of the Hip
J Bone Joint Surg Am. 2007 Feb;89(2):339-46.
Amstutz HC,
Antoniades JT,
Le Duff MJ.
Background:
Modern hip resurfacing implants may increase stability and preserve bone
compared to conventional total hip arthroplasty. The purpose of this retrospective
study was to analyze the mid-term results of a consecutive series of middle-aged
patients with developmental dysplasia of the hip treated by hybrid resurfacing
joint arthroplasty.
Materials and Methods:
Conserve? Plus Metal-on-metal resurfacing was performed in 54 patients
(59 hips), 43 females and 11 males. The average age at the time
of surgery was 43.7 years. Radiographic and clinical data were collected
at 3 months and at yearly follow-up. Seven hips had Crowe class type II
and fifty-two had type I developmental dysplasia of the hip.
Results:
The follow-up period ranged from 4.2 years to 9.5 years (average 6.0 years).
Initial stability was achieved in all but 3 patients. Clinical outcome
using the UCLA hip scores showed significant improvement from pre-operative
ratings. Pain ratings improved from 3.2 to 9.3, walking from 6.0
to 9.8, function from 5.7 to 9.7, and activity from 4.6 to 7.5 (all, p<0.0001).
SF-12 mental scores increased from 46.6 to 53.4 and physical scores from
31.7 to 52.0 (all, p<0.0001). The mean post-operative Harris
hip score was 93.0. Range of motion improved in flexion from106.5? to
129.4?, the abduction-adduction arc from 41.9? to 77.5?, and the rotation
arc in extension from 32.1? to 85.4? (all, p<0.0001). Four patients
have delivered six healthy babies since implantation. Radiographic analysis
showed a decrease in body weight lever arm from 118.5 mm pre-op to 103.9
mm post-op (p=0.007). There were 5 femoral failures requiring conversion
to a total hip arthroplasty One hip showed a femoral radiolucency around
the metaphyseal stem. There were no complete acetabular radiolucencies
and all sockets remained well fixed.
Conclusions:
The mid-term results of metal-on-metal resurfacing in Crowe type I and
II developmental dysplasia of the hip were disappointing, with respect
to the durability of the femoral component. The more recent results with
meticulous bone preparation have been effective in eliminating femoral
neck fractures and loosening in the past 6 years. The fixation of
the Conserve? Plus porous coated acetabular components without adjuvant
fixation has been excellent from the beginning of implantations despite
incomplete lateral acetabular coverage of the socket. (See Abstract “The
Effects of Technique Changes on Aseptic Loosening of the Femoral Component
in Hip Resurfacing. Results of 600 Conserve? Plus With a 3 to 9 Year Follow-up”)